Component Function Check
1.CHECK PARKING BRAKE SWITCH OPERATION
Check that brake warning lamp in combination meter turns ON/OFF when parking brake is operated.
Is the inspection result normal? YES >> Inspection End.
NO >> Proceed to BRC-115, "Diagnosis Procedure".
Diagnosis Procedure
1.CHECK PARKING BRAKE SWITCH CIRCUIT


Is the inspection result normal? YES >> GO TO 2.
NO >> Repair or replace error-detected parts.
2.CHECK PARKING BRAKE SWITCH
Check the parking brake switch. Refer to PB-4, "Inspection and Adjustment".
Is the inspection result normal? YES >> GO TO 3.
NO >> Replace the parking brake switch. Refer to PB-7, "Exploded View".
3.CHECK PARKING BRAKE SWITCH SIGNAL
With CONSULT

Is the inspection result normal? YES >> Inspection End.
NO >> GO TO 4.
4.CHECK COMBINATION METER
Check the combination meter. Refer to MWI-21, "CONSULT Function (METER/M&A)".
Is the inspection result normal? YES >> GO TO 5.
NO >> Repair or replace combination meter. Refer to MWI-82, "Removal and Installation".
5.CHECK TERMINAL
Is the inspection result normal? YES >> Replace the ABS actuator and electric unit (control unit). Refer to BRC-136, "Removal and Installation".
NO >> Repair or replace error-detected parts.
Component Inspection
1.CHECK PARKING BRAKE SWITCH

Is the inspection result normal? YES >> Inspection End.
NO >> Replace the parking brake switch. Refer to PB-7, "Exploded View".
Power supply and ground circuit
VDC off switchFront wiper motor HI circuit
Component Function Check
1.CHECK FRONT WIPER HI OPERATION
CONSULT ACTIVE TEST
Select FR WIPER of BCM (WIPER) active test item.
Check front wiper operation.
HI : Front wiper (HI) operation
OFF : Front wiper OFF
Is the inspection result normal?
YES >> Front wiper motor ...
Ignition coil
Exploded View
Ignition coil
Spark plug
Rocker cover
Removal and Installation
REMOVAL
Remove air duct assembly. Refer to EM-24, "Exploded View" .
Disconnect the harness connector from the ignition coil.
Remove the ignition coil.
CAUTION:
...
Symptom diagnosis
SQUEAK AND RATTLE TROUBLE DIAGNOSES
Work Flow
CUSTOMER INTERVIEW
Interview the customer if possible, to determine the conditions that exist
when the noise occurs. Use the Diagnostic
Worksheet during the interview to document the facts and conditions when the
noise occurs and any
custome ...