Diagnosis Procedure
1.PERFORM INITIALIZATION PROCEDURE
Initialization procedure is executed and operation is confirmed.
Refer to PWC-27, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special Repair Requirement".
Is the inspection result normal? YES >> Inspection End.
NO >> GO TO 2.
2.CHECK ENCODER CIRCUIT
Check encoder circuit.
Refer to PWC-45, "Component Function Check".
Is the inspection result normal? YES >> GO TO 3.
NO >> Repair or replace the malfunctioning parts.
3.CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal? YES >> Check intermittent incident. Refer to GI-41, "Intermittent Incident".
NO >> GO TO 1.
Rear RH side power window does not operate
Power window retained power operation does not operate
properlyInstrument panel assembly
Exploded View
Defroster grille
Center speaker grille (if equipped)
Side ventilator grille (LH)
Instrument side finisher (LH)
Knee protector
Instrument finisher A
Cluster lid A
Instrument finisher B (without pushbutton
ignition)
Instrument finishe ...
C1769 configuration setting
DTC Description
This procedure must be performed:
After replacement of BCM.
DTC DETECTION LOGIC
DTC
Display Item
Malfunction detected condition
C1769
CONFIG SETTING
(Configuration setting)
Tire air pressure monitoring system configuration cannot be
p ...
P0448 EVAP canister vent control valve
DTC Description
DTC DETECTION LOGIC
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
P0448
VENT CONTROL VALVE
(Evaporative emission system vent control
circuit shorted)