Nissan Rogue manuals

Nissan Rogue Service Manual: Anti-pinch system does not operate normally (driver side)

Diagnosis Procedure

1.PERFORM INITIALIZATION PROCEDURE

Initialization procedure is executed and operation is confirmed.

Refer to PWC-27, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special Repair Requirement".

Is the inspection result normal? YES >> Inspection End.

NO >> GO TO 2.

2.CHECK ENCODER CIRCUIT

Check encoder circuit.

Refer to PWC-45, "Component Function Check".

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair or replace the malfunctioning parts.

3.CONFIRM THE OPERATION

Confirm the operation again.

Is the result normal? YES >> Check intermittent incident. Refer to GI-41, "Intermittent Incident".

NO >> GO TO 1.

Rear RH side power window does not operate
WITH BOTH POWER WINDOW MAIN SWITCH AND REAR POWER WINDOW SWITCH RH WITH BOTH POWER WINDOW MAIN SWITCH AND REAR POWER WINDOW SWITCH RH : Diagnosis Procedure 1.CHECK REAR POWER WINDOW SWITCH Check ...

Power window retained power operation does not operate properly
Diagnosis Procedure 1.CHECK DOOR SWITCH Check door switch. Refer to DLK-149, "Component Function Check" (with Intelligent Key system) or DLK-319, "Component Function Check" ...

Other materials:

Instrument panel assembly
Exploded View Defroster grille Center speaker grille (if equipped)  Side ventilator grille (LH)  Instrument side finisher (LH) Knee protector Instrument finisher A  Cluster lid A Instrument finisher B (without pushbutton ignition)  Instrument finishe ...

C1769 configuration setting
DTC Description This procedure must be performed:  After replacement of BCM. DTC DETECTION LOGIC DTC Display Item Malfunction detected condition C1769 CONFIG SETTING (Configuration setting) Tire air pressure monitoring system configuration cannot be p ...

P0448 EVAP canister vent control valve
DTC Description DTC DETECTION LOGIC DTC No. CONSULT screen terms (Trouble diagnosis content) DTC detecting condition P0448 VENT CONTROL VALVE (Evaporative emission system vent control circuit shorted) EVAP canister vent control valve remains closed under specif ...